M 系列M-series

M 系列提供高 vCPU 计数(最多 128 个vCPU)和大量内存(最高 3.8 TiB)。The M-series offers a high vCPU count (up to 128 vCPUs) and a large amount of memory (up to 3.8 TiB). 它也非常适用于极大型数据库或受益于高 vCPU 计数和大量内存的其他应用程序。It's also ideal for extremely large databases or other applications that benefit from high vCPU counts and large amounts of memory. Intel® Xeon® CPU E7-8890 v3 @ 2.50GHz 和 Intel® Xeon® Platinum 8280M (Cascade Lake) 均支持 M 系列大小。M-series sizes are supported both on the Intel® Xeon® CPU E7-8890 v3 @ 2.50GHz and on the Intel® Xeon® Platinum 8280M (Cascade Lake).

M 系列 VM 采用 Intel® 超线程技术。M-series VM's feature Intel® Hyper-Threading Technology.

ACU:160-180ACU: 160-180

高级存储:支持Premium Storage: Supported

高级存储缓存:支持Premium Storage caching: Supported

实时迁移:不支持Live Migration: Not Supported

内存保留更新:不支持Memory Preserving Updates: Not Supported

写入加速器:支持Write Accelerator: Supported

大小Size vCPUvCPU 内存:GiBMemory: GiB 临时存储 (SSD) GiBTemp storage (SSD) GiB 最大数据磁盘数Max data disks 最大缓存吞吐量和临时存储吞吐量:IOPS/MBps(以 GiB 为单位的缓存大小)Max cached and temp storage throughput: IOPS/MBps (cache size in GiB) 最大非缓存磁盘吞吐量:IOPS/MBpsMax uncached disk throughput: IOPS/MBps 最大 NIC 数/预期网络带宽 (Mbps)Max NICs/Expected network bandwidth (Mbps)
Standard_M8msStandard_M8ms 88 218.75218.75 256256 88 10000/100 (793)10000/100 (793) 5000/1255000/125 4/20004/2000
Standard_M16msStandard_M16ms 1616 437.5437.5 512512 1616 20000/200 (1587)20000/200 (1587) 10000/25010000/250 8/40008/4000
Standard_M32tsStandard_M32ts 3232 192192 10241024 3232 40000/400 (3174)40000/400 (3174) 20000/50020000/500 8/80008/8000
Standard_M32lsStandard_M32ls 3232 256256 10241024 3232 40000/400 (3174)40000/400 (3174) 20000/50020000/500 8/80008/8000
Standard_M32msStandard_M32ms 3232 875875 10241024 3232 40000/400 (3174)40000/400 (3174) 20000/50020000/500 8/80008/8000
Standard_M64s 1Standard_M64s 1 6464 10241024 20482048 6464 80000/800 (6348)80000/800 (6348) 40000/100040000/1000 8/160008/16000
Standard_M64ls 1Standard_M64ls 1 6464 512512 20482048 6464 80000/800 (6348)80000/800 (6348) 40000/100040000/1000 8/160008/16000
Standard_M64ms 1Standard_M64ms 1 6464 17921792 20482048 6464 80000/800 (6348)80000/800 (6348) 40000/100040000/1000 8/160008/16000
Standard_M128s 1Standard_M128s 1 128128 20482048 40964096 6464 160000/1600 (12696)160000/1600 (12696) 80000/200080000/2000 8/300008/30000
Standard_M128ms 1,2Standard_M128ms 1,2 128128 38923892 40964096 6464 160000/1600 (12696)160000/1600 (12696) 80000/200080000/2000 8/300008/30000
Standard_M64 1Standard_M64 1 6464 10241024 71687168 6464 80000/800 (1228)80000/800 (1228) 40000/100040000/1000 8/160008/16000
Standard_M64m 1Standard_M64m 1 6464 17921792 71687168 6464 80000/800 (1228)80000/800 (1228) 40000/100040000/1000 8/160008/16000
Standard_M128 1Standard_M128 1 128128 20482048 1433614336 6464 250000/1600 (2456)250000/1600 (2456) 80000/200080000/2000 8/320008/32000
Standard_M128m 1Standard_M128m 1 128128 38923892 1433614336 6464 250000/1600 (2456)250000/1600 (2456) 80000/200080000/2000 8/320008/32000

1 超过 64 vCPU 的 VM 需要以下受支持的来宾 OS 之一:Windows Server 2016、Ubuntu 16.04 LTS、SLES 12 SP2 和 Red Hat Enterprise Linux、CentOS 7.3 或带 LIS 4.2.1 的 Oracle Linux 7.3。1 More than 64 vCPU's require one of these supported guest OSes: Windows Server 2016, Ubuntu 16.04 LTS, SLES 12 SP2, and Red Hat Enterprise Linux, CentOS 7.3 or Oracle Linux 7.3 with LIS 4.2.1.

2 实例对于专用于单个客户的硬件独立。2 Instance is isolated to hardware dedicated to a single customer.

大小表定义Size table definitions

  • 存储容量的单位为 GiB 或 1024^3 字节。Storage capacity is shown in units of GiB or 1024^3 bytes. 比较以 GB(1000^3 字节)为单位的磁盘与以 GiB(1024^3 字节)为单位的磁盘时,请记住以 GiB 为单位的容量数显得更小。When you compare disks measured in GB (1000^3 bytes) to disks measured in GiB (1024^3) remember that capacity numbers given in GiB may appear smaller. 例如,1023 GiB = 1098.4 GB。For example, 1023 GiB = 1098.4 GB.

  • 磁盘吞吐量的单位为每秒输入/输出操作数 (IOPS) 和 MBps,其中 MBps = 10^6 字节/秒。Disk throughput is measured in input/output operations per second (IOPS) and MBps where MBps = 10^6 bytes/sec.

  • 数据磁盘可以在缓存或非缓存模式下运行。Data disks can operate in cached or uncached modes. 对于缓存数据磁盘操作,主机缓存模式设置为 ReadOnlyReadWriteFor cached data disk operation, the host cache mode is set to ReadOnly or ReadWrite. 对于非缓存数据磁盘操作,主机缓存模式设置为 NoneFor uncached data disk operation, the host cache mode is set to None.

  • 若要获得 VM 的最佳性能,应将数据磁盘数限制为每 vCPU 2 个磁盘。If you want to get the best performance for your VMs, you should limit the number of data disks to two disks per vCPU.

  • 预期的网络带宽是指跨所有 NIC 为每个 VM 类型分配的最大聚合带宽,适用于所有目标。Expected network bandwidth is the maximum aggregated bandwidth allocated per VM type across all NICs, for all destinations. 有关详细信息,请参阅虚拟机网络带宽For more information, see Virtual machine network bandwidth.

    无法保证上限。Upper limits aren't guaranteed. 限值用于在为目标应用程序选择适当的 VM 类型时提供指导。Limits offer guidance for selecting the right VM type for the intended application. 实际的网络性能将取决于多种因素,包括网络拥塞、应用程序负载和网络设置。Actual network performance will depend on several factors including network congestion, application loads, and network settings. 有关如何优化网络吞吐量的信息,请参阅为 Azure 虚拟机优化网络吞吐量For information on optimizing network throughput, see Optimize network throughput for Azure virtual machines. 若要在 Linux 或 Windows 中达到预期的网络性能,可能需要选择特定版本,或者需要优化 VM。To achieve the expected network performance on Linux or Windows, you may need to select a specific version or optimize your VM. 有关详细信息,请参阅带宽/吞吐量测试 (NTTTCP)For more information, see Bandwidth/Throughput testing (NTTTCP).

其他大小Other sizes

后续步骤Next steps

了解有关 Azure 计算单元 (ACU) 如何帮助跨 Azure SKU 比较计算性能的详细信息。Learn more about how Azure compute units (ACU) can help you compare compute performance across Azure SKUs.