Dadsv5-series utilize AMD's third Generation EPYCTM 7763v processors that can achieve a boosted maximum frequency of 3.5GHz. The Dadsv5-series sizes offer a combination of vCPU, memory, and temporary storage for most production workloads. The new VMs have 50% larger local storage and better local disk IOPS for both read and write compared to the Dav4/Dasv4 sizes with Gen2 VMs.
Dadsv5-series virtual machines support Standard SSD, Standard HDD, and Premium SSD disk types. You can also attach Ultra Disk storage based on its regional availability. Disk storage is billed separately from virtual machines.
1Temp disk speed often differs between RR (Random Read) and RW (Random Write) operations. RR operations are typically faster than RW operations. The RW speed is usually slower than the RR speed on series where only the RR speed value is listed.
Storage capacity is shown in units of GiB or 1024^3 bytes. When you compare disks measured in GB (1000^3 bytes) to disks measured in GiB (1024^3) remember that capacity numbers given in GiB may appear smaller. For example, 1023 GiB = 1098.4 GB.
Disk throughput is measured in input/output operations per second (IOPS) and MBps where MBps = 10^6 bytes/sec.
Storage capacity is shown in units of GiB or 1024^3 bytes. When you compare disks measured in GB (1000^3 bytes) to disks measured in GiB (1024^3) remember that capacity numbers given in GiB may appear smaller. For example, 1023 GiB = 1098.4 GB.
Disk throughput is measured in input/output operations per second (IOPS) and MBps where MBps = 10^6 bytes/sec.
Data disks can operate in cached or uncached modes. For cached data disk operation, the host cache mode is set to ReadOnly or ReadWrite. For uncached data disk operation, the host cache mode is set to None.
Expected network bandwidth is the maximum aggregated bandwidth allocated per VM type across all NICs, for all destinations. For more information, see Virtual machine network bandwidth
Upper limits aren't guaranteed. Limits offer guidance for selecting the right VM type for the intended application. Actual network performance will depend on several factors including network congestion, application loads, and network settings. For information on optimizing network throughput, see Optimize network throughput for Azure virtual machines.
To achieve the expected network performance on Linux or Windows, you may need to select a specific version or optimize your VM. For more information, see Bandwidth/Throughput testing (NTTTCP).
Accelerator (GPUs, FPGAs, etc.) info for each size